Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Article | IMSEAR | ID: sea-219309

ABSTRACT

Introduction: Left ventricular (LV) diastolic dysfunction is common on preoperative screening among patients undergoing surgery. There is no simple screening test at present to suspect LV diastolic dysfunction. This study was aimed to test the hypothesis, whether elastic recoil signal (ERS) on tissue Doppler imaging of mitral annulus (MA TDI) can be used as a qualitative test to differentiate patients from normal LV diastolic function versus patients with LV diastolic dysfunction. Methods: This was a prospective cross-sectional observational study of patients admitted for elective surgeries. Normal diastolic function and categorization of LV diastolic dysfunction into severity grades I, II, or III were performed as per the American Society of Echocardiography/ European Associationof Cardio Vascular Imaging (ASE/EACVI) recommendations for LV diastolic dysfunction. Results: There were 41 (61%) patients with normal LV diastolic function and 26 (39%) patients with various grades of LV diastolic dysfunction. In 38 out of 41 patients with normal LV diastolic function, the characteristic ERS was identified. The ERS was absent in all the patients with any grade of LV diastolic dysfunction. Consistency of identification of ERS on echocardiography was tested with a good interobserver variability coefficient of 0.94 (P-value <0.001). The presence of ERS demonstrated an excellent differentiation to rule out any LV diastolic dysfunction with an area under the receiver operating characteristics curve (AUROC) of 0.96 (CI 0.88�99; P value <0.001). Conclusions: To conclude, in a mixed surgical population, the anesthetist could successfully assess LV diastolic dysfunction in the preoperative period and the characteristic ERS on MA TDI signal can be used as a qualitative test to differentiate patients from normal LV diastolic function versus patients with LV diastolic dysfunction using the transthoracic echocardiography (TTE).

2.
Ann Card Anaesth ; 2019 Apr; 22(2): 177-186
Article | IMSEAR | ID: sea-185876

ABSTRACT

Background: Ultrasound (US)-guided internal jugular vein (IJV) cannulation is a widely accepted standard procedure. The axillary vein (AV) in comparison to the subclavian vein is easily visualized, but its cannulation is not extensively studied in cardiac patients. Aims: This study is an attempt to study the efficacy of real-time US-guided axillary venous cannulation as a safe alternative for the time-tested US-guided IJV cannulation. Design: This is a prospective randomized controlled study. Materials and Methods: A total of 100 adult patients scheduled for cardiac surgery were divided equally in Group A-US-guided IJV cannulation, and Group B-US-guided axillary venous cannulation. Under local anesthesia and real-time US guidance the IJV or AV was secured. The access time, guidewire time, and procedure time were noted. Furthermore, the number of needle attempts, malposition, change of site, and complications were noted. Results: The data were analyzed for 49 patients in Group A and 48 patients in the Group B due to exclusions. The access time and the guidewire time were comparable in both groups. The first attempt needle puncture was successful for the IJV group in 98% of patients in comparison to 95% of patients in Group B. Guidewire was passed in the first attempt in 94% in Group A and 89% in the Group B. Except for arterial puncture in one case in group A, the complications were insignificant in both groups. Conclusion: The study shows that the US-guided AV cannulation may serve as an effective alternative to the IJV cannulation in cardiac surgery.

SELECTION OF CITATIONS
SEARCH DETAIL